Shown with manual doubletimer control systemTechnical specificationsInstallation instructionsOperating instructionsMaintenanceIPSO - USA3101 South Hav
Page 1050 lb. Dryer Dimensions - Standard Gas, Steam and Electric HeatedsnoitacificepSerusaeM.S.UcirteMerusaeMyticapaC)neniLyrD(.sbl05gk7.22teksaBrete
Page 11DR50 Dryer Dimensions - Gas(Illustration)34.87“ (880 mm)33.07“ (840 mm)34.87“ (890 mm)49.5“(1260 mm)12.2“(310 mm)9.25“(235 mm)6.3“(160 mm)12.
Page 12Electric connectionThe connection needs to be made in the wiring box at the back. Remove thecoverplate (G) in order to reach the connection cla
Page 13The gas supply pipe should be connected to the gas tap (I), which is on the right nextto the wiring box on the back.It is very important to hav
Page 14Gas Piping Installation1. The installation must conform with local codes, or inthe absence of local codes with the National FuelGas Code as, AN
Page 15Gas Piping Installation (Illustrations)The dryer and it’s individual shutoff valve must be disconnected from the gas supplypiping system during
Page 16The size of the gas service pipe is dependant upon manyvariables, such as tees, lengths, etc. Specific pipe sizeshould be obtained from the gas
Page 17Gas Pipe Size ChartTOTAL BTU/HR(for LP Gas correcttotal BTU/HR below bymultiplying by .6)TOTALKCALHOURGAS PIPE SIZE FOR 1000 BTU (250 KCAL) NAT
Page 18Dryer Installation With Multiple ExhaustFor Exhaust Duct less than 14 feet (5 m) and2 elbows equivalent and less than 0.3 inches (8 mm)static p
Page 19Dryer Installation with Multiple ExhaustFor Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalentand more than 0.3 inches (8 mm) static
Page 2IMPORTANT NOTICES—PLEASE READFor optimum efficiency and safety, we recommend that you read the manual before operating theequipment. Store thi
Page 20 Suggested Minimum Dryer Make-up Air RequirementsDryer Dryer Pocket Maximum Air Flow Duct Size For Required Make-upModel Capacity
Page 21Dryer Installation With Separate Exhaust (Preferred)For ductwork less than 14 feet (5 m) and 2 elbows equivalentand less than 0.3 inches (8 mm)
Page 22Nothing is more important than air flow for the proper operation of aclothes dryer. A dryer is a pump which draws make-up air from theout-of-do
Page 23Rules for Safe Operation of Dryer1. Be sure your dryer is installed properly in accordance with therecommended instructions.2. CAUTIONBe safe—s
Page 24NOTE: All dryers manufactured are equipped with the DSI(direct spark ignition) modules. These are designed to increasedryer efficiency and t
Page 25DIRECT SPARKIGNITION OPERATIONFLOW CHARTThe DSI module is powered by a 24 volts AC suppled by a step-down trans-former in series with eight saf
Page 26General MaintenanceGENERALMAINTENANCE1. Clean lint trap daily. Remove lint before or aftereach day of operation. A clean lint trap will increas
Page 277. Periodically clean and examine exhaust system.8. Keep dryer area clean and free of gasoline,combustible materials and other flammable liquid
Page 28OPERATING INSTRUCTION - DOUBLE TIMER1. After loading the dryer with water washed clothes, close the loading door.2. Turn the 60 minute drying (
Page 29Ref. Part No. DescriptionNo.1 CSA50037WH Jacket fas/electric (white)1 CSA-50050WH Jacket steam (white)2 TU7733 Screw self drilling 8-18 X 1/2&
Page 3 ATTENTION: L’ACHETEUR DOIT PLACER L’AVERTISSEMENT SUIVANT DANS UN ENDROIT CLAIR ET VISIBLE: ATTENTION: L’ACHETEU
Page 30CSA-01423WH Complete control door assy.Note: Door rod assy. is not part of above complete assy.Ref. Part No. Description No.1 CSA-01424WH
Page 31Ref. Part No. DescriptionNo.1 SB-00915-0 Screw self drilling #10-16 X 5/82 CSA-01566WH Front panel, welded assy.-Coin2 CSA-01565WH Front panel,
Page 32Ref. Part No. DescriptionNo.1 EA-00607-0 Thermostat knob2 CA-13213-0 Thermostat bracket3 EA-00606-0 Thermostat4 CA-13215-0 Thermostat bracket a
Page 3324531212267WIRE BOX ASSEMBLYRef. Part No. DescriptionNo.CSA-01608WH Wire box door assy complete1 TUT316 Light LED 24V2 EA-11614-0 Timer-manual
Page 34Ref. Part No. DescriptionNo.MSD-00864WH Complete door assy (consists of items 1 thru 9 only)1 MD-00362-0 Door Glass - clear2 MD-00354-0 Gasket
Page 35Ref. Part No. DescriptionNo.CSA-01430WH Complete Asm - WMC50 OPLCSA-01428WH Complete Asm - WMC50 Coin1 CSA-01099WH Lint door w/latch holes(whit
Page 36Ref. Part No. DescriptionNo.CSA-01541-0 Basket & Spyder Asm.WMC50 - S.S.CSA-01632-0 Basket & Spyder Asm.WMC50 - Galv.1 CSA-01540-0 Stai
Page 37Ref. Part No. DescriptionNo.1 CA-12073-0 Top panel2 TU7733 Screw self drilling 8-18*1/2"3 CA-11936-0 Cover plate4 CA-12016-0 Backpanel5 TU
Page 38Ref. Part No. DescriptionNo.CSA-01334-0 Sail switch assy. complete1 CA-11854-0 Bracket sailswitch2 SB-00955-0 Screw phillips #4 X 3/4"3 TU
Page 39Ref. Part No. DescriptionNo.1 DA-11912-0 Pulley - basket2 Part of pulley3 DA-11914-0 Key4 C249 Hex nut 5/16-18"5 SB-00876-0 Stud - 5/16 -
Page 4WARNING: To avoid fire hazard, do not dry articles containing foam rubber or similartexture materials. Do not put into this dryer flammable ite
Page 40Ref. Part No. DescriptionNo.1 DA-00494-0 Fan motor 1/2 HP 115/208/230/60/50/11 DA-00447-0 Fan motor 1/2 HP 220/380/60/50/32 TU2814 Lock washer
Page 41Ref. Part No. DescriptionNo.1 DA--11904-0 Idler pulley 11"2 DA-00917-0 Basket belt - non-reversing - AX702 DA-00497-0 Basket belt -reversi
Page 42Ref. Part No. DescriptionNo.ESA-00966-0 Wire box assy, rear, gas - 115V - 2 timerESA-00974-0 Wire box assy, rear, gas - 208/240V - 2 timer1 CA-
Page 43Ref. Part No. DescriptionNo.GSA-0778-0 Comp. assy. - Nat. gas1 GSA-00255-0 Housing gas burner2 TU11613-0 Lock washer 10 external tooth3 SB-0083
Page 5IPSO DRYER WARRANTYIPSO warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship fora p
Page 6ContentsSafety Instructions ...2-4Cissell Dryer Warranty ...
Page 7Rotation in two directionsRotation dans les deux sensDrehbewigung in zweiRichtungenMovimiento rotativo en losdos sentidosCautionAttentionAchtung
Page 8Unpacking/General Installation (All Dryers)Upon arrival of the equipment, any damage in shipmentshould be reported to the carrier immediately.Up
Page 9Unpacking/General Installation (All Dryers)The dryer is so designed that when an operator opens thedryer door, the basket and exhaust fan stop.
Comments to this Manuals