Tumblers – T30 and T45
4-08-43
19
For T45 Gas Models (For Total Machine):
Serial Plate
Voltage
Terminal Block
Connections
Required
Current
(Amps)
Recommended Fuse
or Breaker Rating
(Amps)
Breaker
Poles
Recommended
Minimum
Conductor Size
(AWG [mm
2
])
208–240V/60Hz/1ph
L1, L2, Neutral and ground 12.0 15 2 14 (2.08)
200–208V/60Hz/3ph
L1, L2, L3 and ground 9.6 15 3 14 (2.08)
240V/60Hz/3ph
L1, L2, L3 and ground 9.6 15 3 14 (2.08)
200V/50Hz/1ph
L1, Neutral and ground 11.2 15 1 14 (2.08)
230-240V/50Hz/1ph
L1, Neutral and ground 10.8 15 1 14 (2.08)
Tabl e 5