DIRECT SPARK
IGNITION OPERATION
FLOW CHART
The DSI module is powered by a 24 volts AC suppled by a step-down trans-
former in series with eight safety interlocks:
A. Timer switching device (1)
B. Main door and lint door switches (2)
C. Sail switch (1)
D. Under basket and burner housing thermal safety switches (2)
E. Variable thermostat (1)
F. Push to start switch (1)
THERMOSTAT
CALLS FOR HEAT
IGNITION CYCLE
BEGINS, GAS VALVE
ON
MAIN BURNER
FLAME DETECTED
CONTROL LOC-OUT
RESET POWER
REQUIRES A
MANUAL RESET
(Opening/closing door,
power switch ON/OFF)
SPARK IGNITION
OFF FLAME MONI-
TOR ON GAS VALVE
ON
FLAME IS LOST DUE
TO POWER OUTAGE,
DOOR OPEN
NO
YES
NO
FLAME IS ON UNTIL
THERMOSTAT OR
TIMER IS SATISFIED
YES