IPSO TMB795C User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Tumblers – 50 and 75
18
4-08-44
50 Pound Gas and Steam Models
Refer to Table 4.
NOTE: Wire sizes were obtained from the
Canadian Electrical Code for 75 C. wire and are
intended for use as a guideline only. Electrical
connections should be made by a qualified
electrical contractor in accordance with all
applicable local and national requirements.
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).
7
Serial Plate Rating
Terminal Block
Connections
Required
Serial Plate Amps Recommended Circuit
Nonreversing Reversing Breaker Rating
Wire Size
AWG (mm
2
)
120V/60Hz/1ph
L1, Neutral and ground 9.3 N/A 15A – 1 pole 14 (2.08)
200-208V/60Hz/1ph
L1, Neutral and ground 5.1 N/A 10A – 1 pole 14 (2.08)
200-208-240V/60Hz/1ph
L1, L2 and ground 5.1 N/A 10A – 2 pole 14 (2.08)
230-240V/50Hz/1ph
L1, Neutral and ground 6.3 6.9 15A – 1 pole 14 (2.08)
200-208V/60Hz/3ph
L1, L2, L3 and ground 2.8 4.0 10A – 3 pole 14 (2.08)
200V/50Hz/3ph
L1, L2, L3 and ground 3.3 4.2 10A – 3 pole 14 (2.08)
240V/60Hz/3ph
L1, L2, L3 and ground 2.8 4.0 10A – 3 pole 14 (2.08)
230-240V/50Hz/3ph
L1, L2, L3 and ground 3.1 4.3 10A – 3 pole 14 (2.08)
380V/50 or 60Hz/3ph
L1, L2, L3 and ground 1.6 2.0 10A – 3 pole 14 (2.08)
400-415V/50Hz/3ph
L1, L2, L3 and ground 1.6 2.0 10A – 3 pole 14 (2.08)
440V/60Hz/3ph
L1, L2, L3 and ground 1.4 1.9 10A – 3 pole 14 (2.08)
460-480V/60Hz/3ph
L1, L2, L3 and ground 1.4 1.9 10A – 3 pole 14 (2.08)
N/A = Not Applicable
Table 4
Page view 18
1 2 ... 14 15 16 17 18 19 20 21

Comments to this Manuals

No comments